Error "Critical error: Object is located in personal Cabinet" is received in Windchill

When performing an action error is received:

"​​Critical error: Object is located in personal Cabinet"


There is a bug in Windchill versions previous to Windchill PDMLink 11.0 M030 CPS15

During Replace with Existing action, the state of WTPart is unexpectedly changed from New to Check Out and Location is unexpectedly changed to Personal Cabinet in Site domain


​​Update to PDMLink 11.0 M030 CPS15 or later

​​1. Check that Windchill services are running. Make sure that no user is working in Windchill.

2. Manually trigger the Windows Scheduled Task called WTBackup. It could take approximately 45 minutes.

3. Open Windchill Shell and run WinDU and choose only "Move EPMWorkspace objects Check". Notice the result of the check.

4. Run WinRU in the same Windchill Shell and choose only "Move EPMWorkspace objects to Default Cabinet Repair". Notice the results.

5. Run WinDU once again and choose only "Move EPMWorkspace objects Check". The results should now display "No objects found..." since the problem should have been solved.